Modified Langendorff Perfusion for Extended Perfusion Times of Rodent Cardiac Grafts

400 조회수

2회 인용됨

06:22 분

2024년 6월 14일

10.3791/66815-v

2024년 6월 14일

400 조회수
 ,  ,  ,  ,  ,  , 

This article demonstrates the feasibility of achieving longer perfusion times (4 h) of murine cardiac grafts without function loss by employing lower (30-35 mmHg) than physiological (60-80 mmHg) perfusion pressures during Langendorff.

더 많은 동영상 탐색

Perfusion Pressure

Chapters in this video

0:00

Introduction

1:09

Cardiac Graft Procurement for Langendorff Perfusion

3:31

Optimizing Langendorff Perfusion Parameters for Enhanced Cardiac Graft Function and Durability

Related Videos