Microfluidic Platform for Measuring Neutrophil Chemotaxis from Unprocessed Whole Blood

366 조회수

20회 인용됨

10:13 분

2014년 6월 3일

10.3791/51215-v

2014년 6월 3일

366 조회수
 ,  ,  ,  ,  , 

* These authors contributed equally

This protocol details an assay designed to measure human neutrophil chemotaxis from one droplet of whole blood with robust reproducibility. This approach circumvents the need for neutrophil separation and requires only a few minutes of assay preparation time. The microfluidic chip enables the repeated measure of neutrophil chemotaxis over time in infants or small mammals, where sample volume is limited.

더 많은 동영상 탐색

Whole Blood Assay

Chapters in this video

0:05

Title

2:22

Microfluidic Device Fabrication

4:19

Microfluidic Assay Preparation

6:11

Sample Preparation: Human Neutrophils From Capillary Blood

6:49

Microscopy and Image Analysis for Neutrophil Chemotaxis Measurements

7:53

Results: Neutrophils Chemotaxis Assay From Whole Blood

8:55

Conclusion

Related Videos