Three-Dimensional Printing of a Complex Aortic Anomaly

322 צפיות

צוטט 3 פעמים

03:40 דק׳

1 בנובמבר 2018

10.3791/58175-v

1 בנובמבר 2018

322 צפיות
 ,  ,  ,  ,  , 

Here, we present a protocol to use three dimensional printed models for pre-operative planning and intra-operative reorganization of complicated vascular locations when handling a congenital aortic anomaly.

גלה סרטונים נוספים

DICOM Imaging

Chapters in this video

0:04

Title

0:31

Region of Interest (ROI) Segmentation

2:01

ROI 3D Model Reconstruction, Printing, and Pre- and Intraoperative Review

2:58

Results: Representative Computed Tomography (CT) Angiography Image Processing

3:22

Conclusion