Isometric Contractility Measurement of the Mouse Mesenteric Artery Using Wire Myography

1.3K 次观看

被引用 16 次

09:42 分钟

2018年8月20日

10.3791/58064-v

2018年8月20日

1.3K 次观看
 ,  ,  ,  ,  , 

The wire myograph technique is used to investigate vascular smooth muscle functions and screen new drugs. We report a detailed protocol for measuring the isometric contractility of the mouse mesenteric artery and for screening new relaxants of vascular smooth muscle.

探索更多视频

Vascular Smooth Muscle

Chapters in this video

0:04

Title

0:55

Mouse Mesenteric Artery Dissection

2:26

Arterial Mounting

5:30

Normalization

7:03

Artery Contraction Recording

8:18

Results: Representative Tracings Showing the Normalization Procedure, Potentiation by High-K+ Solution, and Contraction

8:47

Conclusion